Global Catalog

Home Global Products Pulsed Heat Fusing Systems Pulse Heat Fusing Unit

Pulse Heat Fusing Unit

Pulse Heat Fusing Unit

NCU-10 : General Purpose Type
NCU-15 : High Power type

  • Rapid heating.
  • Temperature feedback loop.
  • Superior temperature control.
  • Good temperature accuracy - Superior to open-circuit control.
  • Overshoot reduction function.
  • Excellent repeatability.
  • Flexible heating and cooling controls.
  • Heating : Temperature rising time;
  • Holding time; Idling function.
  • Cooling : Cooling temperature.

 

Pulsed Heat Fusing Units    

Items

NCU-10

NCU-15

Heating Temp

Main : room temp. - 499

Idling : room temp - 299

Post-Heat : room temp- 299

Heating Time

0.1-9.9sec (0.1sec step)

Power Source

AC100V ± 10% 1Φ

AC200V ± 10% 1Φ
(Option : 100, 115, 230V)

Air

0.4MPa or more

-

Dimensions

W200 x D302 x H90mm ≈ 3.5kg

W200 x D302 x H120mm ≈ 4.1

Transformers

Items

NCU-10

NCU-15 (NT-15)

NCU-15 (NT-35)

Rating Power

150VA

1500VA

3000VA

Tap Voltage

1.75V, 2.5V, 3.5V

1.0V, 2.0V, 3.0V

1.0V, 2.0V, 3.0V

Dimensions

W100 x D150 x H120mm
≈ 3.4kg

W160 x D220 x H200mm
≈ 14.2kg

W200 x D270 x H220mm
≈ 25kg

 

               
        

                 

Image Gallery

Additional Info

Last modified on Friday, 20 May 2011 20:57